Volume 6, Issue 2 (2-2024)                   Tabari Biomed Stu Res J 2024, 6(2): 36-43 | Back to browse issues page


XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Abedini A, Kiani O, Fakharian A, Rezaei M A, Salimi M. Diagnostic Value of Oxygen Desaturation Index in Sarcoidosis Patients Suspected to Have Obstructive Sleep Apnea. Tabari Biomed Stu Res J 2024; 6 (2) :36-43
URL: http://tbsrj.mazums.ac.ir/article-1-3835-en.html
1- Masih Daneshvari Hospital, Tehran University of medical science.
2- Clinical Research Development Center, Imam Reza Hospital, Kermanshah University of Medical Sciences, Kermanshah, Iran
Abstract:  
sarcoidosis patients are at increased risk for obstructive sleep apnea syndrome (OSAS) probably due to factors such as steroid use, obesity, sarcoid neuropathy and etc. Therefore, we aimed to define the diagnostic value of the oxygen desaturation index (ODI) in predicting OSAS in patients with sarcoidosis. This cross-sectional study was performed in 81 sarcoidosis patients suspected to have OSAS admitted to the pulmonary clinics of the Masih Daneshvari Hospital, affiliated with Shahid Beheshti University of Medical Sciences.Patients were examined using the Epworth Sleepiness Scale (ESS) and the Fatigue Assessment Scale(FAS), and those with FAS score≥ 22 and ESS score > 10 were included. All patients underwent a portable polysomnography(PSG) and a high-resolution pulse oximeter wristwatch simultaneously. Of 81 patients, 57(70.4%) were female and 24(29.6%) were male, and the mean age was 48.9±10.4 years (range, 28 to 75). The AHI score was positively correlated with ESS and ODI scores (r=0.51, p<0.001; r= 0.85, p<0.001, respectively). A positive correlation was found between ODI and ESS (r=0.57, p<0.001). A kappa coefficient value of 0.26 indicated a fair agreement between AHI and ODI scores. The cutoff based on maximal accuracy for ODI to predict AHI ≥15 was ODI ≥15. ODI ≥15 has been indicated to have sensitivity of 100%, and hence NPV of 100%, specificity of 96.4%, PPV of 36.6%, and 99.9 of accuracy for predicting moderate and severe OSAS. ODI from a high-resolution pulse oximeter wristwatch is a sensitive and specific tool to predict moderate and severe OSAS in sarcoidosis patients.
Type of Study: Research (Original) | Subject: Internal Medicine
Published: 2024/02/21 | ePublished: 2024/02/21